421502l1.txt ;******************************************************************************** ; LISTING 1 - FOR THE MATED CONNECTIONS ; ; "Testing and modeling yields a better cable assembly," EDN, June 10, 2004, pg 85 ; ; http://www.reed-electronics.com/ednmag/article/CA421502 ;******************************************************************************** * Time Domain Analysis Systems: IConnect .subckt Connector_Model port1 port2 port3 port4 gnd_ ****** Partition #1 t1 port1 gnd_ 1 gnd_ Z0=92 TD=53.4p t2 port3 gnd_ 2 gnd_ Z0=92 TD=53.4p t3 port1 port3 1 2 Z0=318 TD=53.4p ****** Partition #2 t4 1 gnd_ 3 gnd_ Z0=98.8 TD=50p t5 2 gnd_ 4 gnd_ Z0=98.8 TD=50p t6 1 2 3 4 Z0=160 TD=50p ***** Subsegment #1 ***** t7 3 gnd_ port2 gnd_ Z0=62.3 TD=111p t8 4 gnd_ port4 gnd_ Z0=62.3 TD=111p t9 3 4 port2 port4 Z0=396 TD=111p .ends